FLIR A6700 MWIR

FLIR A400/A500/A700 Science Kits

FLIR A400, A500, and A700 Science Kits offer researchers and engineers a streamlined solution for accurate temperature measurement. Simplified yet robust connections help you set up and start testing quickly; then easily view, acquire, and analyze data using included FLIR Research Studio software.

The Standard kit includes a FLIR A400, A500, or A700 Image Streaming camera, 24° lens with automatic/remote and manual focusing, as well as FLIR Macro Mode.

The Professional kit has the added benefits of MSX® image enhancement, radiometric data transmission over Wi-Fi, and a close-up lens for accurate thermal measurements on small components.

Markus Tarin - CEO & President of MoviTHERM

Call 949-699-6600 to speak with a product specialist.

Unparalleled Thermal Imaging & Innovations

Get accurate thermal data on your entire device and individual subcomponents

  • Obtain correct thermal measurements with crisp remote, automatic, and manual focusing
  • Multiple lens options ensure you get the maximum number of pixels on your test article
  • Accurately measure temperatures on small objects without the need to switch lenses using the included one-touch enabled FLIR Macro Mode
  • Better differentiate between features and components with the patented FLIR MSX® image enhancement*

Simplified Data Analysis, Sharing, and Collaboration

Start collecting and sharing meaningful data with limited ramp-up time and simple connections

  • Employ FLIR Research Studio’s simple Connect➞View➞Record➞Analyze workflow to obtain and analyze thermal results quickly
  • Work in the operating system you prefer and share data globally with colleagues in their preferred language
  • Stream fully radiometric compressed data over Wi-Fi to devices running FLIR Research Studio*

Advanced Features for Unmatched Connectivity

Get up and running faster with simple yet robust connections

  • Ensure camera connections are correct and secure with M-style, positive lock connectors
  • Eliminate the need for additional cables using standard Power over Ethernet (PoE)
  • Connect the camera to your workstation using Wi-Fi for camera control, data recording and image analysis*
  • Control camera parameters and recording through digital I/O

FLIR A400 A500 A700 Science Kits Technical Specifications

Detector Data Standard Kit Professional Kit
IR resolution 320 × 240 (A400), 464 × 348 (A500), or 640 × 480 (A700)
Thermal resolution/NETD <30 mK to <50 mK – Lens dependent
Focal plane array/spectral range Uncooled Microbolometer
Detector pitch 24 μm, 17 μm, or 12 μm – camera dependent
Spectral range 7.5–14.0 µm
Frame Rate 30 Hz
Image and Optical Data
Camera f/# Lens Dependent
Included Lenses 24° 24°, 2.0X Macro
Optional Lenses 2.0X Macro, 6°, 14°, 42° 6°, 14°, 42°
Macro Mode Included
Lens identification Automatic
Focus One-shot contrast, motorized, manual
Minimum focus distance 2.0X Macro: 18 mm (0.71 in)
24°: 0.15 m (0.49 ft)
24° f/1.0: 0.3 m (0.98 ft)
24° with Macro Mode: 17 mm (0.67 in)
42°: 0.15 m (0.49 ft)
14°: 1.0 m (3.28 ft)
6°: 5.0 m (16.4 ft)
Visual Camera Optional 5 Megapixel
Measurement
Standard Temperature Ranges -20°C to 120°C (-4°F to 248°F)
0°C to 650°C (32°F to 1202°F)
A400/A500: 300°C to 1500°C (572°F to 2732°F)
A700: 300°C to 2000°C (572°F to 3632°F)
Accuracy ±2°C (±3.6°F) or ±2% of reading for ambient temperature
15°C to 35°C (59°F to 95°F),
object temperature above 0°C (32°F)
Image Presentation
Digital data Via workstation running included Research Studio Software
Data Streaming & Control Gigabit Ethernet
(RTSP, GigE Vision)
Gigabit Ethernet
(RTSP, GigE Vision), Wi-Fi
Dynamic Range 16-bit
Image Modes in Research Studio
Infrared Yes
Visual Yes
MSX® Yes
Gigabit Ethernet
Ethernet Image Streaming Yes
Connector type M12 8-pin X-coded, female
Ethernet power Power over Ethernet, PoE IEEE 802.3af class 3
Ethernet communication GigE Vision ver. 1.2, Client API GenICam compliant, TCP/IP socket-based (FLIR proprietary)
Digital input/output
Connector type M12 Male 12-pin A-coded (shared with ext. power)
Digital input 2× opto-isolated, Vin (low) = 0–1.5 V, Vin (high) = 3–25V
Digital output 3× opto-isolated, 0–48 VDC, max. 350 mA (derated to 200mA at 60°C). Solid-state opto relay, 1× dedicated as fault output (NC)
Wi-Fi (optional)
Connector type Optional Female RP-SMA
Standard Optional IEEE802.11a/b/g/n
Connections Optional Peer to peer (ad hoc) or infrastructure (network)
Power system
Connector type M12 Male 12-pin A-coded (shared with Digital I/O)
General Power over Ethernet or External
External voltage 24/48 VDC, 8 W max
General
Operating Temperature Range –20°C to 40°C (–4°F to 104°F) (in free air)
40°C to 50°C (104°F to 122°F)
(mounted on cooling plate accessory)
Maximum camera case temperature: 65°C (149°F)
Storage Temperature Range IEC 68-2-1 and IEC 68-2-2, –40°C to 70°C (–40°F to 158°F) for 16 hours
Encapsulation IEC 60529, IP 54, IP66 with accessory
Shock IEC 60068-2-27, 25 g
Vibration IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal
Power 24/48 V DC 8 W max
Size 123 mm × 77 mm × 77 mm (4.84 in × 3.03 in × 3.03 in)
Weight (including 24° lens) 0.82 kg (1.8 lb)
Mounting UNC ¼”-20 on 2 sides
4× M4 on 4 sides

 

Available Options:

91902-0202 – A400 Standard Science Kit
91903-0102 – A400 Professional Science Kit
90610-0202 – A500 Standard Science Kit
90611-0102 – A500 Professional Science Kit
85903-0202 – A700 Standard Science Kit
85903-0102 – A700 Professional Science Kit