129LC – Liquid Cooled Housing for Daylight & Thermal Cameras
129LC is a liquid-cooled CCTV camera housing specifically designed for industrial high-temperature applications (steelworks, foundries, furnaces, rolling mills). The 129LC is made of two concentrically stainless steel tubes forming a liquid chamber that cools down the camera. The front plate is conceived to create an air barrier that cools and protects the glass from the formation of dust and deposits, especially useful when the housing is located near ovens or dusty places.
The Tecnovideo ABFL-01 Air Filtering system is recommended to grant clean air to the front window, filtering out water and oil particles. The enclosure is entirely made in electropolished stainless steel AISI316L, suitable for harsh industrial installations. These housings are engineered to ensure the best protection from external agents and to allow an easy installation and maintenance.
We’re here to help you!
We are an official partner!
20+ years experience!
Call us to learn more!
Specifications
General & Mechanical | |
---|---|
Dimensions | See dimensions drawings |
Operating Temperature | See “Temperature” section |
Cooling System | Liquid cooling (main system), window air barrier (window cooling) |
Construction | AISI316L Stainless Steel |
Finish | Electro-polished |
Window | Borosilicate (visible), Zinc Selenide or Germanium AR/DLC coated (thermal) |
Mounting | See drawings |
Cable entries | 2 M20x1,5 threaded holes. Cable glands not included |
Wiper | Window air barrier |
Weight | Unit: 13kg / Package: 14kg |
Temperature | |
Borosilicate glass window (housing model 129LC) |
External: 392°F/200°C Internal: 74°F/23°C External: 572°F/300°C Internal: 92°F/33°C External: 752°F/400°C Internal: 113°F/45°C |
Germanium window (housing model 129LCIRG70) | External: 176°F/80°C Internal: 59°F/15°C |
Zinc Selenide window (housing model 129LCIRZ70) |
External: 392°F/200°C Internal: 74°F/23°C External: 572°F/300°C Internal: 92°F/33°C |
Temperatures may differ depending on environmental factors, water flow/termperature and air flow. Internal tests performed using ~6 l/min [~1,59 US gal/min] water flow and ~6 bar air pressure in front air barrier. |
|
Certifications | |
Ingress Protection | EEN 60529 (IP66/IP67) |
RoHS | 2011/65/EU + 2015/863/EU (RoHS 3) |
WEEE | 2012/19/EU |
Models | |
129LC(1) | LIQUID-COOLED camera housing, MEDIUM size, Borosilicate (Borofloat®) front window, for applications up to 300°C (572°F) with peaks of 400°C (752°F) |
129LCIRG70(2) | LIQUID-COOLED camera housing, MEDIUM size, Germanium window Ø: 70mm, for applications up to 80°C (176°F) |
129LCIRZ70(3) | LIQUID-COOLED camera housing, MEDIUM size , Zinc-Selenide window Ø: 70mm, for applications up to 300°C (572°F) with peaks of 400°C (752°F) |
1 Thickness: 5 mm 2 Thickness: 3 mm. Germanium, AR/DLC coating. 3 Thickness: 5 mm. Zinc Selenide with AR/AR coating |
|
Accessories | |
SSBK-M | Wall mounting bracket |
SSPM-M | Pole mount adapter for SSBK-M |
ABFL-01 | Air filtering group of three filters: 20 μm, 5 μm, 0.1μm in cascade, with pressure regulator, pressure gauge and wall fixing bracket. |