FLIR A6700 MWIR

Thermal Camera for Critical Equipment Monitoring

FLIR A310 Infrared Camera

Fixed-mounted thermal imaging cameras like the FLIR A310 can be installed almost anywhere to monitor your critical equipment and other valuable assets. It will safeguard your plant and measure temperature differences to assess the criticality of a given situation. This allows you to see problems before they become costly failures, preventing downtime and enhancing worker safety.

This camera model is end of life (EoL).

We do not recommend this for new projects.
This camera is being replaced by FLIR A400 Smart Sensor.

Learn More

mio a310

Compatible with MoviTHERM MIO-A310

The MIO series I/O modules allow the design of robust industrial monitoring applications. The industry standard 4 to 20 mA interface and 24VDC alarm outputs of the MoviTHERM MIO Series Intelligent I/O module provide a cost effective remote monitoring solution.

Learn More

Excellent image quality

Both thermal imaging cameras contain an uncooled Vanadium Oxide (VOx) microbolometer detector. They produce crisp thermal images of 320 x 240 pixel and detects temperature differences as small as 50 mK. They come with a built-in 25° lens with motorized focus. Other fields of view are available.

Stream MPEG-4 video over Ethernet to show live images on a PC. 640×480 with overlay up to 30 Hz. Ethernet-enabled, communication and power can be supplied with only one cable. Composite video outputs, PAL and NTSC compatible are available. Both cameras can be controlled remotely over the Web using TCP/IP protocol.

Industrial protocol

Since FLIR A310 is Ethernet/IP and Modbus TCP compliant analysis and alarm results can easily be shared to a PLC. Digital inputs/outputs are available for alarms and control of external equipment. An image masking function allows you to select only the relevant part of the image for your analysis.

Built-in analysis and alarm functions

FLIR A310 comes standard with built-in analysis functions like spot, area measurement and difference temperature. Alarms can be set to go off as a function of analysis, internal temperature or digital input. The camera automatically sends analysis results, IR images and more as an e-mail on schedule or at alarm. Autonomous dispatch of files or e-mails, acting as an FTP- or SMTP-client is possible.

Protective housing

The FLIR A310 can be ordered already built into an environmental housing. The housing increases the environmental specifications of the FLIR A310 to IP66, without affecting any of the camera’s features. It is ideal when the camera needs to be installed in dusty or wet environments. The housing is available for A300 cameras that are equipped with 7, 15, 25, 45 or 90° FOV lenses. Users that want to build the camera within the housing themselves or that already have a FLIR A310 that needs extra protection against dust and water can order the housing separately as an accessory.

High Temperature Options

For high temperature applications the camera can be calibrated for high temperature ranges.

FLIR P/N Description
T197000

High temperature option +1200°C (+2192°F)

  • +200°C to +1200°C (+392°F to +2192°F)
T129252

Special temperature range –20 to +700°C

  • –20 to +120°C (–4 to +248°F)
  • 0 to +700°C (+32 to +1292°F)
T129253

Special temperature range –20 to +500°C

  • –20 to +120°C (–4 to +248°F)
  • –20 to +500°C (–4 to +932°F)
T129254

High temperature measurement option –20 to +2000°C

  • –20 to +120°C (–4 to +248°F)
  • 0 to +500°C (+32 to +932°F)
  • +300 to +2000°C (+572 to +3632°F)

FLIR A310 Technical Specifications

System Overview FLIR A310 (FLIR Part Number 48201-1101)
Spotmeter 10
Area 10 boxes with max./min./average/position
Isotherm 1 with above/below/interval
Measurement option Measurement Mask Filter Schedule response: File sending (ftp), email (SMTP)
Difference temperature Delta temperature between measurement functions or reference
temperature
Reference temperature Manually set or captured from any measurement function
Atmospheric transmission correction Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correction Automatic, based on signals from internal sensors
Emissivity correction Variable from 0.01 to 1.0
Reflected apparent temperature correction Automatic, based on input of reflected temperature
External optics/windows correction Automatic, based on input of optics/window transmission and temperature
Measurement corrections Global and individual object parameters
Field of view (FOV) / Minimum focus distance 25° × 18.8° / 0.4 m (1.31 ft.)
Lens identification Automatic
Thermal sensitivity/NETD < 0.05°C at +30°C (86°F) (86°F) / 50 mK
Focus Automatic or manual (built in motor)
F-number 1.3
Image frequency 30 Hz
Zoom 1–8× continuous, digital, interpolating zooming on images
Alarm
Alarm functions 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm output Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Detector data
IR resolution 320 × 240 pixels
Detector pitch 25 μm
Detector time constant Typical 12 ms
Focal Plane Array (FPA) / Spectral range Uncooled microbolometer / 7.5–13 μm
Measurement
Object temperature range –20 to +120°C (-4 to 248°F)
0 to +350°C (32 to 662°F)
* High Temperature Options available, see Features tab
Accuracy ±2°C (3.6°F) or ±2% of reading
Set-up
Color palettes Color palettes (BW, BW inv, Iron, Rain)
Set-up commands Date/time, Temperature °C /°F
Storage media
Image storage type Built-in memory for image storage
File formats Standard JPEG, 16-bit measurement data included
Composite video
Video out Composite video output, PAL and NTSC compatible
Video, standard CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Digital input/output
Digital input 2 opto-isolated, 10–30 VDC
Digital output, purpose As function of ALARM, Output to ext. device (programmatically set)
Digital output 2 opto-isolated, 10–30 VDC, max 100 mA
Digital I/O, isolation voltage 500 VRMS
Digital I/O, supply voltage 12/24 VDC, max 200 mA
Digital I/O, connector type 6-pole jackable screw terminal
Digital input, purpose Image tag (start/stop/general), Input ext. device (programmatically read)
Ethernet
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, type 100 Mbps
Ethernet, communication TCP/IP socket-based FLIR proprietary
Ethernet, power Power over Ethernet, PoE IEEE 802.3af class 0
Ethernet Control, result and image
Ethernet, protocols Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet, image streaming 16-bit 320 x 240 pixels at 7-8 Hz -Radiometric
Environmental data
Storage temperature range –40°C to +70°C (-40° to 158°F)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (77 to 104°F)
EMC
  • EN 61000-6-2:2001 (Immunity)
  • EN 61000-6-3:2001 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
Vibration 2 g (IEC 60068-2-6)
Physical data
Housing material Aluminium
Scope of delivery
Cardboard box, Infrared camera with lens, Ethernet cable, FLIR Tools download card, Mains cable, Power cable – pig-tailed, Power supply, Printed documentation, User documentation CD-ROM, Utility CD-ROM

Introducing the FLIR A310 Thermal Imaging Camera For Critical Equipment Monitoring

 

Getting Started with the FLIR A310 Thermal Imaging Camera for Automation

 

Setting up your FLIR A310 Thermal Imaging Camera using FLIR IR Monitor