FLIR A6700 MWIR

Fully Compliant with ATEX Regulations

FLIR A310 ex

Explosive atmospheres need to be protected from ignition sources. Selecting equipment and protective systems which meet the requirements of the ATEX Product Regulations or similar regulations is essential.

FLIR A310 ex is an ATEX compliant solution, with a thermal imaging camera mounted in an enclosure, making it possible to monitor critical and other valuable assets also in explosive atmospheres. Typical applications for the A310 ex include process monitoring, quality control, and fire detection in explosive locations. Because the FLIR A310 ex is rated IP 67, it can be installed in dusty environments.

The Flame-Proof Enclosure “d” prevents any explosion transmission from the inside of the enclosure to the outside.

Lens Options:
25° × 18.8° with 18 mm (0.7 in.) lens (FLIR Part Number 71001-1103)
45° × 33.8° with 9.66 mm (0.38 in.) lens (FLIR Part Number 71001-1104)

Markus Tarin - CEO & President of MoviTHERM

Call 949-699-6600 to speak with a product specialist.

more ...

Compatible with MoviTHERM MIO-A310

mio a310The MIO series I/O modules allow the design of robust industrial monitoring applications. The industry standard 4 to 20 mA interface and 24VDC alarm outputs of the MoviTHERM MIO Series Intelligent I/O module provide a cost effective remote monitoring solution.
more ...

FLIR A310 ex

The thermal imaging camera inside the FLIR A310 ex is a FLIR A310. This camera is equipped with both measurement and alarm functionalities. For a more detailed description of the FLIR A310 thermal imaging camera, ask for FLIR A310 product leaflet or consult FLIR.com.

Integrated controller

The integrated controller features several digital I/O channels and sensors for temperature, humidity and pressure. Among other functions, the I/O channels enable the user to switch on/off the camera and the heater via remote control. The access is accomplished through an integrated web interface or Modbus TCP/IP. The integrated controller is equipped with two fiber optic and two Ethernet parts. This enables a flexible network integration in star or ring topologies.

Heater FLIR

A310 ex comes with a heater which effectively prevents fogging and freezing of the protection window.

Verification Certificate

ZELM 12 ATEX 0485 X The FLIR A310 ex is ATEX-certified. It can be installed in classification zones 1, 2, 21 and 22. The certification comprises the whole system, which includes the enclosure, as well as all components inside, such as the thermal imaging camera, heater and integrated controller.

High Temperature Options

For high temperature applications the camera can be calibrated for high temperature ranges.

FLIR P/N Description
T197000

High temperature option +1200°C (+2192°F)

  • +200°C to +1200°C (+392°F to +2192°F)
T129252

Special temperature range –20 to +700°C

  • –20 to +120°C (–4 to +248°F)
  • 0 to +700°C (+32 to +1292°F)
T129253

Special temperature range –20 to +500°C

  • –20 to +120°C (–4 to +248°F)
  • –20 to +500°C (–4 to +932°F)
T129254

High temperature measurement option –20 to +2000°C

  • –20 to +120°C (–4 to +248°F)
  • 0 to +500°C (+32 to +932°F)
  • +300 to +2000°C (+572 to +3632°F)

FLIR A310 ex Technical Specifications

General Data
Ambient temperature range for operation –20°C to +40°C (-4°F to 104°F)
Protection class IP67
Weight 6.7 kg (without camera and lens)
Empty volume 5.06 l
External dimensions (without sun shield) D = 170 mm, L = 408 mm
Housing material / Surface Nickel-plated aluminium / Powder coated
Protection window Germanium, double-sided AR Coated, externally with additional hard-carbon layer
Maximum power of the additional heater 16 W
Operating voltage 24 V DC
Maximum electric connection power 60 W
Power cable / Power cable configuration Helukabel 37264 / Pigtail
Length of power cable 4 m (13 ft.)
Integrated controller 4-port switch with 2 × fiber-optic LC 100Base-FX or 2 × RJ45(10/100) up-links, ring-topology support for reduced cabling effort, 2 × internal temperature sensors, air humidity and pressure sensor, digital output module controllable via Modbus TCP/IP or web interface to enable turning the heater on/off
Ethernet medium Multi-mode breakout fiber AT-V(ZN)Y(ZN)Y 4G50/125 OM2
Length of Ethernet cable 4 m (13 ft.)
Ethernet, configuration Pigtail with FC connector
Explosion protection-specific data
For use in EX zone 1, 2, 21, and 22
Ignition protection category Flame-proof enclosure “d”
Maximum surface temperature (according to temperature class T6) Maximum 85°C
ATEX certification (version -AXC) EX-Protection Gas: II 2G Ex d IIC T6 Gb, EX-Protection Dust: II 2D Ex tb IIC T85° Db
Verification certificate ZELM 12 ATEX 0485 X
Imaging and optical data
IR resolution 320 × 240 pixels
Thermal sensitivity/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Field of view (FOV) / Focal length 25° × 18.8° with 18 mm (0.7 in.) lens   (FLIR Part Number 71001-1103)
45° × 33.8° with 9.66 mm (0.38 in.) lens   (FLIR Part Number 71001-1104)
Minimum focus distance 0.4 m (1.31 ft.)
Spatial resolution (IFOV) 1.36 mrad with 25° lens or 2.59 mrad with 45° lens
Lens identification Automatic
F-number 1.3
Image frequency 30 Hz
Focus Automatic or manual (built in motor)
Zoom 1–8× continuous, digital, interpolating zooming on images
Detector data
Detector type Focal Plane Array (FPA), uncooled microbolometer
Spectral range 7.5–13 μm
Detector pitch 25 μm
Detector time constant Typical 12 ms
Measurement
Object temperature range –20 to +120°C (–4 to +248°F)
0 to +350°C (+32 to +662°F)
* High Temperature Options available, see Features tab
Accuracy ±2°C (±3.6°F) or ±2% of reading
Measurement analysis
Spotmeter 10
Area 10 boxes with max./min./average/position
Isotherm 1 with above/below/interval
Measurement option Measurement Mask Filter Schedule response: File sending (ftp), email (SMTP)
Difference temperature Delta temperature between measurement functions or reference temperature
Reference temperature Manually set or captured from any measurement function
Atmospheric transmission correction Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correction Automatic, based on signals from internal sensors
Emissivity correction Variable from 0.01 to 1.0
Reflected apparent temperature correction Automatic, based on input of reflected temperature
External optics/ windows correction Automatic, based on input of optics/window transmission and temperature
Measurement corrections Global and individual object parameters
Alarm
Alarm functions 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm output Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Set-up
Color palettes Color palettes (BW, BW inv, Iron, Rain)
Set-up commands Date/time, Temperature°C/°F
Storage of images
Storage media Built-in memory for image storage
File formats Standard JPEG, 16-bit measurement data included
Ethernet
Ethernet Control, result and image
Ethernet, type / standard 100 Mbps / IEEE 802.3
Ethernet, configuration Pigtail with FC-connector (fiber)
Ethernet, communication TCP/IP socket-based FLIR proprietary
Ethernet, video streaming MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
Ethernet, image streaming 16-bit 320 × 240 pixels @ 7-8 Hz – Radiometric
Ethernet, protocols Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Shipping information
Infrared camera with lens, in explosion-proof housing, cardboard box, Printed documentation, User documentation CD-ROM, Utility CD-ROM